3.2
DOUBLE OUTLET INSTALLATION DRAFT
Suction
With this system, a check valve (1) must be fitted on the delivery tube to prevent the transfer of sewage inside the
Rotary blades vacuum pump.
3.2.1
DIAGRAM OF INSTALLATION WITHOUT MANIFOLD ON IRRIGATION MACHINES
3.3
ASSEMBL Y AND FITTING - INSTALLATION
The Rotary blades vacuum pump should be assembled and installed using the following procedure:
1) Assemble the Rotary blades vacuum pump horizontally with its feet facing downwards. The assembly position on the vehicle
should be easy to access and be protected. A 5° maximum longitudinal slope of the Rotary blades vacuum pump with respect to the
horizontal plane must not be exceeded.
2) Bolt the Rotary blades vacuum pump using screws and nuts passing through the specially provided slots or holes in the feet;
3-M/K) To install the .../M-K version Rotary blades vacuum pump, connect the cardan shaft at 540 r.p.m.of the tractor to the P.T.O.
shaft of the Rotary blades vacuum pump.
3-MA/KA) To install the .../MA-KA version Rotary blades vacuum pump, connect the cardan shaft at 1000 r.p.m.of the tractor to
the P.T.O. shaft of the Rotary blades vacuum pump.
Don't exceed the maximum slope allowed for the cardan shaft.
The Rotary blades vacuum pump can be used as a mixer
by fitting, on request, a double outlet on the manifold (see
Figure 2). In this case there will be the intake of a normal
Compression
Rotary blades vacuum pump, but a perforated tube placed
inside the tank car must be used for the compression.
When the handle is positioned on the compression phase, the
air will be forced out through the holes in the tube so causing
mixing of the previously loaded sewage (never exceed the
maximum working absolute pressure of 2,5 bar) equal to 1,5
relative bar.
1
Figure 2
Battioni Pagani® produces a complete line of rotary blades vacuum pumps
for use on irrigation machines.
To use the rotary pump correctly, the irrigation machine must be completely
filled with water and must not be partially empty.
Important: never exceed the relative maximum operating pressure
1
of 3.5 bar.
With this system, the delivery pipe must be equipped with a
check valve (1) to prevent water from backing up into the
rotary blades vacuum pump.
for use and maintenance serie MEC, STAR
instruction manual