NOTE!
Only bit numbers 0 - 7 (X5/1 - 8 connectors) are available in Retro Fit mode.
The desired characteristic / job number must be selected using bit coding. For
example:
-
-
-
-
-
-
-
Available job number range:
-
-
Available characteristic number range:
-
-
NOTE!
Characteristic / job number "0" allows a characteristic / job to be selected on the
power source control panel.
Changing/
For power sources in the TPS series, the material, the wire diameter, and the protective
Assigning Cha-
gas shield can be selected using the program number. A bit width of 8 bits was defined
racteristic Num-
for this.
bers/Program
It is possible to assign a program number to a characteristic number (1-255) so that the
Numbers (Retrofit
8-bit signal can be used in retrofit mode.
Mode)
Connector
Standard mode
X5/5
X5/6
X5/7
X5/8
X7/6
X7/7
X7/8
X7/12
X7/13
X7/14
X7/15
X7/16
00000001 = characteristic / job number 1
00000010 = characteristic / job number 2
00000011 = characteristic / job number 3
....
10010011 = characteristic / job number 147
....
11111111 = characteristic / job number 255
Bit number 0-15 = 0 - 1000
Bit number 0-7 (Retro Fit) = 0 - 255
Bit number 0-15 = 256 - 65535
Bit number 0-7 (Retro Fit) = 0 - 255 When using Retro Fit mode, the relevant cha-
racteristic numbers (1 - 255) must be assigned the IDs of the desired characte-
ristics, as otherwise the characteristic cannot be selected via the interface -
see
Changing/Assigning Characteristic Numbers/Program Numbers (Retrofit
Mode)
on page 33.
OC mode
24 V
0 V
24 V
0 V
24 V
0 V
24 V
0 V
24 V
0 V
24 V
0 V
24 V
0 V
24 V
0 V
24 V
0 V
24 V
0 V
24 V
0 V
24 V
0 V
Bit number
4
5
6
7
8
9
10
11
12
13
14
15
33