User Code
Code C0
Setting the factory-adjusted modes of operation
(
5.2.2)
0* =
No action
1 =
Set default values
(state 1 is only shown briefly)
After the confirmation OK, this operating mode can be
acquired in the permanent memory (C10).
Code C1
Selecting the definition of the imbalance value in steps
Selecting the resolution of unbalance readings in
from 0.05 or 0.25 oz. (respectively 1 or 5 grams).
1 or 5 g, or 0.05 or 0.25 oz increments
0*
=
0,25 oz (5 grams) definition
0* =
5 g (0.25 oz) increments
1
=
0,05 oz (1 gram) definition
1 =
1 g (0.05 oz) increments
After the confirmation OK, this operating mode can be
acquired in the permanent memory (C10).
Code C2
Selecting suppression of minor unbalance
readings
0 =
Suppression off
1* =
Suppression on
After the confirmation OK, this operating mode can be
acquired in the permanent memory (C10).
Code C3
Selecting unbalance readings in grams or ounces,
active when the machine is switched on
1* =
Readings in ounces
0* =
Readings in grammes
0 =
Readings in grams
1 =
Readings in ounces
After the confirmation OK, this operating mode can be
acquired in the permanent memory (C10).
Code C4
Electrical compensation of residual unbalance, if
any, in the clamping means
Measurement with increased precision (this mode
cannot be transferred into the permanent memory).
Compensation has to be cancelled and carried out
* = Factory adjusted mode