1
80
5-45
26
5-46
16
29
5-46a
5-47
5-47a
Operation
The Optimization "OP.9" screen (Fig. 5-45) is displayed.
Fig. 5-45 Optimization "OP.9"
START is signalled on the screen.
Spinn the wheel.
A measuring run is performed.
The screen Optimization "OP.10", outside (Fig. 5-46)
or the screen Optimization "OP.10", inside (Fig. 5-47)
is displayed.
Reading H 0
Optimum condition has been achieved and cannot be
improved.
Continue as shown on screen BALANCING
(Fig. 5-51).
Reading H 2
a)
Wheel running conditions cannot be improved.
Press ESC or STOP (1,16, Fig.5-46a) to quit
Optimization.
b)
However, it is possible to readjust the tire relative to
the rim to obtain a quite considerable minimization of
balance weights (i.e. smaller weights) without having
an adverse effect on wheel running conditions.
Press Minimization (29, Fig.5-46a)
Splitting faults
At this stage of the program the faults index is available
(Fig.5-47a).
Press XXX.
Two values appears, indicating how the total wheel
unbalance is split as a percentage between the
rim and the tire;
r
= % unbalance attributable to the Rim
t
= % unbalance attributable to the Tire
Continue as shown on screen Optimization
"OP.10" (Fig. 5-46b).