Models with integrated pump:
The HLW 18TI and PFS 10TI are supplied in a carrying case, including safety block. The HWL
18TI also includes a 4 mm Allen key and the special raising block.
5.3 Component drawings
Only original components may be used. The warranty lapses if non-OEM components are used.
Component drawings are available on request. Please send your request to info@bega.nl.
5.4 Solving common problems
Problem
Pump loses pressure
Lever rises after every stroke
Pump not delivering hydraulic oil
Pump does not achieve full pressure
Lever / pedal feels 'spongy'
6. Disposal
6�1 In accordance with statutory regulations
All materials must be disposed of in accordance with the statutory regulations, or returned to
the supplier.
7. Disclaimer
The manufacturer and/or supplier cannot be held liable for any damage or consequential
damage resulting from incorrect use of the device or damage to workpieces and any
consequential damage resulting from a defect in the device.
14
Cause
1. Oil leak in system
2. Internal pump leak
Internal leakage
1. Too little oil in the reservoir
2. Pump is not lying horizontally
3. Internal leakage
4. Quick-coupler not securely
connected
1. Too little oil in the reservoir
2. Oil leak in system
3. Internal leaks or seal damaged in
pump.
1. Air in the system
2. Too much hydraulic oil in the
reservoir
Solution
1. Check the system and repair
where necessary. Replace leaking
accessories.
2. Send the pump for repair.
Send the pump for repair.
1. Retract the cylinders and top up
the hydraulic oil.
2. Put the pump in a horizontal
position
3. Send the pump for repair.
4. Check the couplers and tighten
securely.
1. Retract the cylinders and top up
the hydraulic oil.
2. Check the system and repair where
necessary.
3. Send the pump for repair.
1. Bleed the system. See section 3.1.
2. Tap off hydraulic oil down to the
correct level.
© BETEX Tools