Do not repair or replace any part of the appliance unless specifically instructed to do so in
this instruction manual. It may lead to a dangerous incident that endangers your health and/
or damages property.
-
In the event of a malfunction, please contact the official Cecotec Technical Support Service.
-
Use original spare parts.
IMPORTANT: do not come into contact with the following internal components while the
appliance is connected: inlet valve(s), drain pump, motor controller heat sink, PCB.
Errors
Error
Cause
E02
No water in
E03
Drain failure
Door lock
U4
fault
Drum
H
temperature
is high
EXX
Other errors
Solution
Check if the tap is open. If the water supply is cut off. Are the
mesh filter in the water supply hose and the water inlet valve
blocked? What if the water supply hose of the appliance is frozen?
Eliminate the above causes of failure. If the fault code still exists,
please contact the Cecotec Technical Support.
Clean the pump filter.
Check if the drain hose is bent, kinked, or blocked. Eliminate the
above causes of failure. If the fault code still exists, please contact
the Cecotec Technical Support.
The door is not closed properly and the door lock does not
function normally. Close the door again, turn the wash cycle
selector to the "OFF" position to turn off the power supply, and
then turn the selector to select any wash programme and press
the START/PAUSE button to restart the programme. Eliminate the
causes of this failure. If the fault code still exists, please contact
the official Cecotec Technical Support Service.
If the fault code appears and you cannot open the door, the door
lock may be faulty, please contact the official Cecotec Technical
Support Service.
Press the START/PAUSE button to suspend operation of the
appliance and wait a few minutes. When the temperature in the
drum drops to a safe range and the fault code on the display is
cleared, press the START/PAUSE button to continue with the rest
of the programme. If the fault code still exists, please contact the
official Cecotec Technical Support Service.
Turn the selector switch to turn off the appliance, unplug the
power cord and contact Cecotec Technical Support.
BOLERO DRESSCODE 8800 INVERTER A / INVERTER STEEL A / INVERTER ICE BLUE A
ENGLISH
119