If the display flashes
This means that:
• you have not placed a pan on the correct cooking zone or,
• the pan you're using is not suitable for induction cooking or,
• the pan is too small or not properly centered on the cooking zone.
No heating takes place unless there is a suitable pan on the cooking zone.
The display will automatically turn off after 1 minutes if no suitable pan is placed on it.
Manual ventilation control
You can control the ventilation setting manually.
NOTE
Using tall items of cookware may prevent the extraction system from working at optimum power. You can improve
the extraction power by placing the lid on the cookware at an angle.
Activating the manual ventilation control
1. In the power-on state, touch
2. Short press the hood key
3. Touch
to switch to boost level.
The ventilation system is activated.
1. Power off
2. Using the hood key
Finish Cooking
Turn the cooking zone off by touching the slider to
"0". Make sure the display shows "0".
Run-on function for the ventilation system
ventilation system is divided into manual and automatic modes.
The automatic mode can be enabled after all the hob is enabled. It will be automatically disabled two minutes
after the hob is all shut down.
Manually
In power on states, touch
Automatically
In power on state,Touch
The appliance deactivates the run-on function when:
• 2 minutes after all hobs are shut down.
• press power key.
alternately with the heat setting
key to activate the ventilation system;
to switch levels from 0-3, long press the hood key
to adjust the level to 0.
or
. Digital screen displays level 0-3 or b.
, digital screen display A.
Turn the whole cooktop off by touching the ON/
OFF control.