4.3 External cellular antenna requirements
The combined gain of the cable and
antenna solution used for this product
must not exceed 2.0 dBi.
The installation room must have stable
network coverage.
The external antenna must be installed
outside the control cabinet.
The external antenna must have an SMA
connector.
An external antenna must always be
connected to the CIM module.
4.3.1 Technical requirements (for US only)
Grundfos does not supply an external antenna with
the product. The antenna must meet applicable RF
regulations. Make sure you choose the antenna
based on the following specifications:
Type
Form factor
Frequency
Bandwidth
Impedance
Polarization
Gain
Click here to see the recommended Grundfos
external cellular antenna.
Dipole
External antenna
700 MHz (SMH700) to
1900 MHz (PCS1900)
LTE Band 4 (445MHz)
LTE Band 5 (70MHz)
LTE Band 12 (47MHz)
LTE Band 13 (41MHz)
LTE Band 25 (145MHz)
LTE Band 26 (80MHz)
LTE Band 66 (490MHz)
LTE Band 85 (48MHz)
50 Ohm
Vertical
< 2.0 dBi
4.4 Radio frequency radiation exposure
information (for Canada and US only)
CAUTION
Radiation
Minor or moderate personal injury
This equipment complies with FCC and
ISED radiation exposure limits set forth
for an uncontrolled environment. This
equipment must be installed and
operated with a minimum distance of
20 cm (0.66 feet) between the radiator
and your body.
This transmitter must not be co-located
or operated in conjunction with any
other antenna or transmitter.
Model: CIM 290-MA LPWAN GIC
The host product needs to be labelled
with the following information:
HMN name:______________________
Contains FCC ID: OG3-CIM290LPWAN
Contains IC: 10447A-CIM290LPWAN.
The enclosed FCC label must be attached near the
nameplate on the product in which the CIM module is
installed. The label must be visible and easily
accessible. Remember to write the host marketing
name (HMN) on the label according to the Installation
and operating instructions of the host product.
Check the manual of the host pump and make sure
that CIM 290 is supported.
This device complies with Part 15 of the
FCC Rules and with license exempt RSSs
of Innovation, Science & Economic
Development Canada.
Operation is subject to the following two conditions:
This device may not cause harmful interference.
This device must accept any interference
received, including interference that may cause
undesired operation.
Changes or modifications made to this
equipment not expressly approved by
Grundfos may void the FCC authorization
to operate this equipment.