C1448, C1848, C2148
Remote Condenser Models - Installation Manual

Adjustments

Bridge Thickness - For A Service Tech Only
1. Push and hold Off till the machine stops.
2. Remove evaporator cover.
3. Remove curtain.
4. Use a box wrench and rotate the bridge
thickness adjustment screw in 1/8 turn
increments CW to increase bridge thickness.
Rotate CCW to decrease bridge thickness.
Caution: Do not make the bridge too thin or the
machine will not harvest properly. Bridge thickness
adjustments are not covered by warranty.
5. Return curtain to its normal position.
6. Push and release the On button. Check next
harvest of ice. Repeat steps 1-6 if needed.
Water purge setting
The water purge is factory set to the automatic
position, suitable for most water conditions. The
setting can be changed to one of 5 manual settings
or left on automatic.
purge
1 -
setting
Minimum
RO water
Water
or
Type
equivalent
To set:
1. Switch the machine OFF by holding the Off
button in until a number or the letter A shows
on the display.
2. Press and release the On button repeatedly
until the number on the display corresponds to
the desired setting.
3. Press and release the Off switch again to
return to the normal control state.
2 -
3 - Standard
Moderate
Factory
Setting for
typical water
June 2007
Page 16
3 - 4 mm
bridge
Too Big
Just Right,
Small Cube
Ice Bridge Thickness Measurement
Ice Thickness Sensor
4 -
5 -
Heavy
Maximum
High TDS
water
Just Right,
Too Small
Medium Cube
A - Automatic
Any with
conductivity not
less than 10
microSiemens/cm