Descargar Imprimir esta página

Key Automation ALT3KF Instrucciones Y Advertencias Para Su Instalación Y Uso página 48

Automatización para barreras viales con mástil desde 3 hasta 8 m

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 86
EN
7 - FURTHER DETAILS - ADVANCED MENU
ALT4K /ALT6K ADVANCED MENU PARAMETERS (CT10324)
The ADVANCED MENU allows the system to be further customised
by modifying parameters not accessible from the basic menu.
To access the ADVANCED menu, press the MENU key and hold
it down for 5 seconds.
CT10324
foto1 setup
1
foto2 setup
2
photo test
3
type edge
4
setup edge
5
test edge
6
flash setup
7
pre setup
8
48
OLD
CT10224
Use of PHOTO1 when starting from closed
SP.h.
0 = PHOTO1 is checked
1 = The barrier starts even with PHOTO1 excited
Use of PHOTO2
Ph.2.
0 = Enabled during both opening and closing
1 =Only enabled during opening
Photocells test
0 = off
tP.h.
1 = PHOTO1 on
2 = PHOTO2 on
3 = PHOTO1 and PHOTO2 on
STOP/EDGE input selection
0 = STOP contact (NC)
1 = Resistive safety edge (8k2)
2 = Contact safety edge (NC)
Ed.m.
3= Double resistive safety edge (4k1)
When an edge is triggered, the automation performs a
brief inversion and then stops if the barrier
Was opening while it causes a reversal of motion if the
barrier was closing
0 = EDGE1 activated only in closing
1 = EDGE1 activated in closing and opening
iE.D.
Attention: If the PAR input is used as EDGE2 then
"SETUP EDGE" must be at 0
Edge test
tE.D.
0 = off
1 = on
Flashing output setup
0 = when opening or closing, the light of the flashing light
is fixed
1 = when opening or closing, the light flashes normally
2 = flashing light on steadily if the barrier is open
3 = electric lock function (12V)
4 = magnetic electric lock function with output active
when barrier is closed (interface with external relay
with 24 Vdc winding)
FP.r.
5 = cabin function. The flash light turns on if any of
the following events occur:
• Motor overtravel
• Encoder error (the barrier continues to operate with
virtual encoder)
• Limit switch error (only for fast barrier)
• 3 consecutive impacts
• Exceeding the number of service manoeuvres
To turn off the flashing light it is necessary to restart the
control board (and remove any causes of error)
Behavior of pre flashing
0 = pre-flashing before each opening and closing
manoeuvre
1 = pre-flashing before each opening manoeuvre
2 = pre-flashing before each closing manoeuvre
If the flash output is not used as light the pre-frashing is
performed only by barrier lights.
To modify ADVANCED MENU parameters, proceed as described
for the BASIC MENU.
DESCRIPTION
DEFAULT MIN MAX
UNIT
1
0
1
0
0
1
0
0
3
1
0
3
0
0
1
0
0
1
1
0
5
0
0
2

Publicidad

loading

Este manual también es adecuado para:

Alt4kAlt6k900alt3kf900alt4k900alt6k