ALT3KF ADVANCED PARAMETERS (CT10324F)
CT10324
foto1 setup
1
foto2 setup
2
photo test
3
type edge
4
setup edge
5
test edge
6
flash setup
7
pre setup
8
pre time
9
50
OLD
CT10224
Use of PHOTO1 when starting from closed
SP.h.
0 = PHOTO1 is checked
1 = The barrier starts even with PHOTO1 excited
Use of PHOTO2
Ph.2.
0 = Enabled during both opening and closing
1 =Only enabled during opening
Photocell test
0 = off
tP.h.
1 = PHOTO1 on
2 = PHOTO2 on
3 = PHOTO1 and PHOTO2 on
STOP/EDGE input selection
0 = STOP contact (NC)
1 = Resistive safety edge (8k2)
2 = Contact safety edge (NC)
3= Double resistive safety edge (4k1)
Ed.m.
When an edge is triggered, the automation
performs a brief inversion and then stops if the
barrier
Was opening while it causes a reversal of motion
if the barrier was closing
0 = EDGE1 activated only in closing
1 = EDGE1 activated in closing and opening
iE.D.
Attention, if the PAR input is used as EDGE2
then "SETUP EDGE" must be at 0
Edge test
tE.D.
0 = off
1 = on
Flashing output setup
0 = when opening or closing, the light of the
flashing light is fixed
1 = when opening or closing, the light flashes
normally
2 = flashing light on steadily if the barrier is open
3 = electric lock function (12V)
4 = magnetic electric lock function with output
active when barrier/door is closed (interface
with external relay with 24 Vdc winding)
FP.r.
5 = cabin box function. The flash light turns on if
any of the following events occur:
• Motor overtravel
• Encoder error (the barrier continues to
operate with virtual encoder)
• Limit switch error (only for fast barrier)
• 3 consecutive impacts
• Exceeding the number of service manoeuvres
To turn off the flashing light it is necessary to
restart the control board (and remove any causes
of error)
Behavior of pre flashing
0: pre-flashing before each opening and closing
manoeuvre
1: pre-flashing before each opening manoeuvre
2: pre-flashing before each closing manoeuvre
If the flash output is not used as light the pre-
frashing is performed only by barrier lights.
Pre-flashing duration time if FLASH out used as
tP.r.
Flash Light
DESCRIPTION
DEFAULT
MIN
MAX
1
0
1
0
0
1
0
0
3
1
0
3
0
0
1
0
0
1
1
0
5
0
0
2
0
0
20
UNIT
s