START PROCEDURE
After selected all the procedure data, press ENTER to continue, the following screen will be
displayed:
Connect and open the coupling connected to the A/C system, then press ENTER, press ESC to
return back.
Open manual valves and press ENTER.
If the vacuum is not sufficient, this screen will be displayed:
Then run a VACUUM procedure.
Instead with sufficient VACUUM the machine will proceed to inject the amount of oil set
INSTRUCTIONS MANUAL
Connect and open HP and LP couplings
to A/C system and press ENTER
Open HP and LP valves
Press ENTER to continue
WARNING !
Insufficient vacuum
Press ESC to exit
-47-
DD/MM/YY XX:XX PM
ESC
ENTER
DD/MM/YY XX:XX PM
ESC
ENTER
DD/MM/YY XX:XX PM
ESC