CHANGE DRYER FILTER
Replace the filter whenever the machine gives the service alarm signals the presence of
humidity in the circuit.
Before performing any operation, check that the replacement filter is the same type as these
installed on the machine.
Then proceed as described below:
1) Wear protective gloves and glasses
2) Connect the machine to the electrical supply and it turn on
3) Note down the release code on the new filters.
IMPORTANT: Filter replacement must be performed as quickly as possible in order to
avoid possible contamination by moisture in the ambient air.
NOTE: If possible, check the seal on the couplings of the new filter, using an electronic leak
tester.
4) From MAINTENANCE, select SERVICE ALARM, the following warning message is
visualized:
An accidental leakage of refrigerant may cause serious damage to skin and eyes, wear
protective gloves and goggles. Make sure that HP and LP coupling are disconnected
from A/C system or else and press ENTER, machine will check presence of refrigerant:
5) And if necessary will recover it
6) Remove the dryer filter, unscrewing the screw (ref 6, Fig.18) and the pipes
INSTRUCTIONS MANUAL
CHANGE DRYER FILTER
Make sure that HP and LP couplings are
Disconnected from A/C system
CHANGE DRYER FILTER
Verifing gas presence in filter
-64-
DD/MM/YY XX:XX PM
ESC
ENTER
DD/MM/YY XX:XX PM
STOP

Publicidad

loading

Este manual también es adecuado para:

Breeze iv