– Under contamination level 2 conditions;
– Under over-voltage category II conditions.
*) Between 5 – 40°C [41 – 104°F] the unit can be operated at a relative humidity of up to 80%.
At temperatures between 31 – 40°C [88 – 104°F], the humidity must decrease proportionally in order to ensure operational
readiness (e.g., at 35°C [95°F] = 65% humidity; at 40°C [104°F] = 50% humidity).
The unit may not be operated at temperatures above 40°C [104°F].
23
Ambient conditions for storage and transport
Ensure the following ambient conditions during storage and transport:
– Ambient temperature –20 – +60°C [ –4 – +140°F],
– Maximum relative humidity 80%.
GB
24
Hazard and Warning Information
Only intended for indoor use. The unit is only designed for dry applications and may not be operated or stored
- 4 -
outdoors or under wet conditions.
The unit may only be operated with a power cord equipped with a plug appropriate to the local power supply.
Regularly inspect connecting lines and hoses (e.g., the power cord) for damage (e.g., kinks, cracks, porosity)
or signs of aging. Units exhibiting damaged connecting lines, hoses, or other defects must be taken out of
service immediately.
Portable and mobile communication devices (e.g. cell phones) can affect the functioning of the unit.
The unit must not be placed directly next to other pieces of electrical equipment. If this is unavoidable,
the unit and the other items of electrical equipment should be checked to rule out any malfunctioning caused
by electromagnetic interference.
Always unplug the unit from the wall outlet before beginning any work on the unit's electrical components.
Note any hazard or warning information provided by the material manufacturer.
Do not operate in an explosion-prone area.
25
Authorized Individuals
This product may not be used by minors under the age of 14.
Only properly trained individuals may operate and service the unit.
Any repairs not specifically described in these operating instructions may only be performed by a qualified electrician
or authorized dealers.
26
Liability Exclusion
Kulzer GmbH shall be absolved from all claims for damages or warranty if:
► The product is used for any purposes other than those cited in the instructions for use;
► The product is altered in any way other than those alterations described in the instructions for use;
► The product is repaired by other than an authorized facility or if any but Kulzer OEM parts are used;
► The product continues to be used, despite obvious safety faults or damage;
► The product is subjected to mechanical impacts or is dropped.
► We do not accept any liability for damage caused by mixing tips, foil bags or cartridges splitting.
3
Product Description
31
General Description
The Dynamix speed unit for mixing impression materials facilitates extrusion and mixing of
2-component dental impression materials.
5 : 1 cartridges or foil bags in cartridge holders from different manufacturers can be used in the unit.
With Dynamix speed, impression materials marked with the symbols
of conventional impression materials using the corresponding mixing program.
The mixing programs control the feed rate of the plungers and the rotational speed of the hexagonal head.
Only use mixing nozzles which are designated for the impression material by the manufacturer.
Cartridges that are not marked with these symbols must be processed using the "ST" program.
A "remaining amount detector" automatically retracts the plungers' disc to the start position so that the cartridges
can be exchanged quickly.
or
can be mixed and extruded in half the time