Client Offset RX
Note: Available with ODUflex CBR and Gb Ethernet client.
For ODUflex CBR, press TEST, BERT, and Client Offset.
For Gb Ethernet, press TEST, Gb Ethernet, and Client Offset.
Configuration
Note: The configuration of the expected frequency offset is available with
ODUflex CBR test only.
Frequency Offset Analysis
Allows to enable the frequency offset measurements. This setting is
enabled by default for normal mode, and disabled for Through mode.
Expected Frequency (bps)
For normal mode, the frequency is set to the configured TX Rate (Refer
to TX Rate on page 407) and the Frequency Offset Analysis check box
is selected.
For Through mode (refer to Creating an OTN (OTU1 and OTU2) Test
Case on page 92), enter the expected frequency in bps and then select
the Frequency Offset Analysis check box.
SONET/SDH Application
Common Tabs
Client Offset RX
BERT
Gb Ethernet
515