PDH Tabs
E0/64K TX
Payload Content
Select the payload content by pressing once or several times on each
timeslot until the desired content appears (or use the Set All buttons).
Choices are Pattern, Idle, and Tone. The default setting is Pattern.
Pattern: Uses the selected pattern from the Pattern TX on page 405.
Idle: Uses the Idle code byte from the Idle field. Choices are 00 to FF.
The selected Idle code applies to all timeslots set to Idle. The default
setting is 7F.
Binary: Allows either displaying the Idle code values in binary (when
enabled) or hexadecimal (when disabled). This setting is disabled by
default.
Tone: Allows the selection of a tone for digital milliwatt testing. The
signal output power, when converted to analog, is 0 dBm. Choices are
1000 Hz and 1004 Hz. The selected Tone applies to all timeslots set to
Tone. The default setting is 1004 Hz.
Payload Content: Allows the selection of the payload content that will
be applied when pressing Set All. Choices are Pattern, Idle, and Tone.
Set All: Allows to set the payload content of all timeslots to the selected
payload content with its Pattern, Idle, or Tone value.
Note: The timeslots set to Idle or Tone can be changed from Idle to Tone and vice
versa even when the test is running; the Idle and Tone values can also be
changed.
372
FTB-8100 Series Transport Blazer