Grundfos CRE Instrucciones De Instalación Y Operación página 35

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7.4.1 "Constant pressure"
Pump variant
CME
CRE, CRIE, CRNE, CRKE, SPKE, MTRE
We recommend this control mode if the pump is to deliver a
constant pressure, independently of the flow in the system. See
fig. 40.
H
Fig. 40 "Constant pressure"
This control mode uses the factory-fitted pressure sensor, if any,
which measures the outlet pressure of the pump.
For pumps without a factory-fitted sensor, you must connect a
pressure sensor to one of the analog inputs of the pump. You can
set the pressure sensor in the "Assist" menu. See section
7.41 "Assisted pump
setup".
Examples
• One external pressure sensor.
p
Fig. 41 "Constant pressure"
"Controller settings"
For recommended controller settings, see section
Controller settings"
7.11 "Controller" ("
Factory setting
See section
10. Technical
data.
"Constant
pressure"
Q
p
).
7.4.2 "Constant temperature"
Pump variant
CME
CRE, CRIE, CRNE, CRKE, SPKE, MTRE
This control mode ensures a constant temperature. Constant
temperature is a comfort control mode that you can use in
domestic hot-water systems to control the flow to maintain a fixed
temperature in the system. See fig. 42.
H
Fig. 42 "Constant temperature"
This control mode requires a temperature sensor placed at the
location where the temperature is to be controlled. See the
examples below:
Examples
t
Fig. 43 "Constant temperature"
"Controller settings"
For recommended controller settings, see section
Controller settings"
7.11 "Controller" ("
Factory setting
See section
10. Technical
data.
"Constant
temperature"
t
Q
t
).
35