Error Messages - SICE S 1000 Manual De Instrucciones

Ocultar thumbs Ver también para S 1000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

is shown on the display.
8A. Press the
button to start the cycle.
The tyre is inflated to a pressure 60% higher than the set value (within maximum pressure
limits). Once the overinflate pressure is reached, the system deflates the tyre to reach the
set value. The pressure is not displayed until the entire inflation and deflation cycle is com-
plete, and three horizontal red bars are shown instead of the value together with a flashing
triangle (Fig. 46c).
Once the cycle is complete, the pressure is displayed again in green and the flashing green
triangle disappears (Fig. 46d).
At this stage, inflation has ended.
9A. Disconnect the Doyfe inflation fitting from the wheel.
10A. Fit the inner core of the valve (Fig. 46a).
Note: Press the "STOP" button
to stop the
automatic inflation cycle at any time.
- The error message A08 ERR_STP is shown on the
display (see Fig. 46e).
46e
- Press the
button to exit the INFLATRON
function and e return to the main screen.
6.1.a ERROR MESSAGES
In the event of anomalies, error messages will appear on the display, and all valves will
be closed.
A01
Loss of calibration coefficients.
- If the problem persists, contact the technical assistance.
A06
Tubeless procedure or overinflation selected.
- Carry out deflation, when necessary.
A08
Operation stopped with the stop key.
A10
The pressure has not increased after several attempts.
Hose not connected
User manual S 1000
156

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido