Installation and commissioning

Setting up the coffee machine

Location

The location where the coffee machine is set up must meet the conditions specified be-
low. If these conditions are not ensured, the coffee machine may become damaged.
Please adhere to the following conditions:
The installation surface must be stable and level so that is does not become deformed un-
der the weight of the coffee machine.
Do not set up the coffee machine on hot surfaces or close to ovens.
Set up the coffee machine in such a way that it can be monitored by trained personnel at
all times.
The required supply terminals must be within 1 m of the machine location according to the
on-site installation plans.
Maintain the following clearances for maintenance work and operation:
Allow enough space above the machine to refill beans.
Leave a clearance of ±35 cm on the left side.
Leave a clearance of min. 15 cm from the rear of the machine to the wall (air circulation).
Leave a clearance of min. 250 mm above the machine (needed to remove the brewing unit for
cleaning and maintenance).
Comply with all applicable local kitchen regulations.

Ambient conditions

The location where the coffee machine is set up must provide the ambient conditions
specified below. If these conditions are not ensured, the coffee machine may become
damaged.
Please adhere to the following conditions:
Ambient temperature of +10 °C to +40 °C (50 °F to 104 °F)
Relative humidity of max. 80% RH
The coffee machine is designed for indoor use only. Do not use in the open and never ex-
pose to the weather (rain, snow, subzero temperatures).
If the coffee machine was exposed to subzero temperatures:
► Contact customer service before commissioning.

Power supply

Conditions

The power supply connection must be made in accordance with the applicable requirements
and the regulations of the respective country. The voltage specified on the serial plate must
match the supply voltage at the installation location.
Danger of electric shock!
Please adhere to the following points:
The phase must be fused at the ampere value specified on the serial plate.
It must be possible to disconnect the device from the mains power supply at all poles.
Never operate a device with a damaged power cable. Have a defective power cable or plug
replaced immediately by a qualified service technician.
Schaerer AG recommends against using an extension cable. If an extension cable is used
despite this (minimum cross-section: 0.75 mm²), please comply with the manufacturer's
Installation and commissioning
BASCJ_EN
V03 | 07.2015