Installation and commissioning
CAUTION!
Risk of machine
damage!
BASCJ_EN
V03 | 07.2015
specifications for the cable (operating instructions) and with locally applicable regulations.
•
Route the power cable in such a way that it does not present a tripping hazard. Do not pull
the cable over corners or sharp edges, pinch it between objects or allow it to hang loosely
in the open. Do not position the cable over hot objects, and protect the cable from exposure
to oil and aggressive cleaning products.
•
Never lift or pull the device by the power cable. Never pull the plug out of the socket by its
cable. Never touch the power cable or plug with wet hands. Never insert a wet plug into a
power socket.
Power requirements
Mains
Power requirements
1L, N, PE
220 – 240 V ~ 50/60 Hz 1700 – 2300 W
Water connection/draining
Conditions
The machine can suffer damage due to bad material and wrong water values.
It is imperative that the following points are complied with:
The water must be free of contaminants and the chlorine content must not exceed 100 mg per
litre.
Do not connect the machine to pure reverse osmosis water or other aggressive types of water.
The carbonate hardness must not exceed 5 – 6°dKH (German carbonate hardness) or 8 –
10°fKH (French carbonate hardness), and the total hardness value must always be greater
than the carbonate hardness.
The minimum carbonate hardness is 4°dKH or 7°fKH. The pH value must be between 6.5 – 7.
Always use the new hose set (fresh water/waste water hose) provided with the machine.
The water supply connection must be made in accordance with the applicable requirements
and the regulations of the respective country. If the machine is connected to a newly installed
water pipe, the pipe and infeed hose must be rinsed well to ensure that no dirt gets into the
machine.
The coffee machine must be connected to an installed drinking water line with a shut-off valve.
Power requirements
Water pressure
Water inlet temperature
Installation
Unpacking the machine
Read the "Setting up the coffee machine" and "Power supply" chapters carefully before install-
ing.
Fuse protec-
tion (site
face)
10 – 16 A
Minimum:
Maximum:
Minimum:
Maximum:
www.schaerer.com
Connecting
cable con-
ductor
cross-sec-
tion
3 x 0.75 mm²
3 x 1 mm²
0.2 MPa (2 bar)
0.6 MPa (6 bar)
10°C
35°C