ADJUSTING GAS CONTROL VALVE MINIMUM SETTING (TOP BURNERS)
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Pull off the knob (A).
2)
Undo the screws (C) and remove the control
3)
panel (B).
Remove the injector (D) , and replace it with
4)
the one suitable for the type of gas in use (see
table at back of manual).
Fully screw the injector.
5)
After making the setting, seal the screw with
6)
paint.
Replace the control panel (B) and the knobs
7)
(A) on completion of the operation.
ADJUSTING GAS VALVE MINIMUM SETTING (OVEN)
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Pull off the knob (A).
2)
Undo the screws (C) and remove the control
3)
panel (B).
Remove the injector (D) , and replace it with
4)
the one suitable for the type of gas in use (see
table at back of manual).
Fully screw the injector.
5)
After making the setting, seal the screw with
6)
paint.
Replace the control panel (B) and the knobs
7)
(A) on completion of the operation.
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Pull off the knob (A).
2)
Undo the screws (C) d remove the control
3)
panel (B).
Undo the screw (D).
4)
Set the burner mount (E) at a distance of 20
5)
mm, and tighten the screw (D).
Replace the control panel (B) and the knobs
6)
(A) on completion of the operation.
3320110_inst_GB_rev.1
ADJUSTING TOP BURNER PRIMARY AIR (7 KW)
A
B
A
B
A
B
- 15 -
D
C
C
C
C
C
C
D
D
GB
D
ENGLISH