ENGLISH
INSTRUCTIONS AND WARNING FOR ADJUSTMENTS
WARNING:In particular, close the gas
supply tap and prevent access to all devices
which might cause unexpected hazards and
damage to people's health and safety if ac-
tivated.
In particular, close the gas supply taps and
prevent access to all devices which might
cause unexpected hazards and damage to
people's health and safety if activated.
NOTE: These adjustments are only re-
quired if the type of gas to be connected is
ADJUSTING THE GAS CONTROL VALVE TO THE MINIMUM SETTING (TOP BURNERS)
To carry out this operation, proceed as follows.
Close the gas supply tap.
1)
Pull off the knobs (A).
2)
Undo the screws (B) and remove the control
3)
panel (C).
Remove the injector (D) and replace it with
4)
the one suitable for the type of gas in use (see
table at the end of the manual).
Fully screw the injector
5)
After making the adjustment, seal the screw
6)
with paint.
After completing the operation, fi t the control
7)
panel (C) and the knob (A) back in place.
ADJUSTING THE TOP BURNER PRIMARY AIR (4 KW)
To carry out this operation, proceed as follows.
Close the gas supply tap.
1)
Pull off the knobs (A).
2)
Undo the screws (B) and remove the control
3)
panel (C).
Loosen the screw (D).
4)
Set the burner mount (E) at a distance of 17
5)
mm and fasten the screw (D).
After completing the operation, fi t the control
6)
panel (C) and the knob (A) back in place.
14
ADJUSTMENTS
diff erent from that used for testing, after
changing the gas supply (see page 11).
ried out by authorised, qualifi ed staff , in ac-
cordance with the relevant legal require-
ments.
WARNING: Adjustments must be car-
A C
B
E
A C
B
3386390_inst_GB_rev.1
ADJUSTMENTS
D
D