It is important to periodically check, through the slot CD,
that the fluid remains at the "max" level.
PLEASE NOTE: THE PICTURES USED IN THIS
MANUAL AND IDENTIFIED BY A NUMBER
CAN BE CONSULTED IN THE ENCLOSED
PUBLICATION CODE 3301039
5 DESCRIPTION OF FUNCTIONS SHOWN ON THE
DISPLAY
when the software was updated, the options installed
and the IP address.
The display then shows the main screen (factory setting).
MIG Process
The operator may start welding immediately and may
adjust the current by turning knob I.
As seen in the figure, the display is divided into sectors.
In each sector, settings operations may be conducted.
The main sector DB is the only one with a red frame. To
select and enable the functions in this sector, press knob
I, choose the function you wish to modify by turning the
knob and the selected functions will turn blue. The name
of the selected function will be displayed on the upper
left.
The welding process DA always appears at the top left
between sectors DB and DN.
DB
DC
DE
When the sector is highlighted in blue, press the knob.
The sector will turn red and the parameters can be adju-
sted using knob I.
All the other sectors are selected by touch.
During
up, for 5 se-
conds the di-
splay presents
all the informa-
tion regarding
the
the serial num-
ber,
tware version,
DG
DH
DF
Touch to select the MIG
TIG
Use the knob to select the process type from among tho-
se listed:
MIG Pulse, Pulse HD, Short, Short HD, Root and Ma-
nual.
TIG DC or DC APC.
start-
MMA DC.
The selected DA welding process always appears at
the top left between sectors DB and DN.
SECTOR DE. SELECTING START MODE.
Touch to select the relevant sector, choosing between
machine,
2T, 4T or 3L.
the
sof-
Mode 2T
The machine begins welding when the torch trigger is
pressed, and stops when released.
When knob I is pressed, the display allows you to adjust
the wire speed by means of a cursor, see fig. 04.
Along with mode 2T the following parameters can be se-
lected:
HSA (Automatic Hot Start), CRA (Final Crater Fill) and
Spot (Spot Welding).
The 3 parameters HSA, CRA and SPOT can be enabled
either at the same time or individually.
Once parameter HSA has been enabled, the operator
can adjust the first current level from 10 to 200% of the
welding current, see fig. 05 - 06.
The first current level time can be adjusted from 0.1 to
10 seconds, see fig. 07 - 08.
The first ramp time between the start current and the
welding current can be adjusted from 0 to 10 seconds,
see fig. 09 - 10.
The wire speed can be adjusted from 1 to 25m/min.
DN
By enabling the parameter CRA, the operator can adjust
DA
the crater current from 10% to 100% of the welding
DM
current, see fig. 11 - 12.
The crater time can be adjusted from 0.1 to 10 seconds,
DL
see fig. 13 - 14.
The final ramp time can be adjusted from 0.1 to 10 se-
conds, see fig. 15 - 16.
The wire speed can be adjusted from 1 to 25m/min.
DI
Mode 4T.
To begin welding, press and release the torch trigger;
to stop welding, press and release it again. Along with
mode 4T the following parameters can be selected:
HSA (Automatic Hot Start), CRA (Final Crater Fill) and
Spot (Spot Welding).
For functions HSA and CRA see mode 2T.
SECTOR DC. CHOICE OF WELDING PRO-
CESS.
Touch to select the relevant sector.
,
or MMA process
see Fig. 03.
see Fig. 03A.
.
25