Specific Earth Resistance (Ro) - KPS Multicheck6010 Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Multicheck6010
Figure 4 38: Example of resistance to earth measurement results
Displayed results:
Re
Resistance to earth
Rs
Resistance of S (potential) probe
Rh
Resistance of H (current) probe
Notes:
• If a voltage of higher than 10 V exists between test terminals, the Earth Resistance
measurement will not be performed.

4.8.2 Specific earth resistance (Ro)

How to perform Specific Earth Resistance measurement
Step 1
Select the Earth Resistance function with the function selector FCT key and select the
Ro mode with the ▲▼ and ◀▶ navigation keys. The following menu will be displayed:
Figure 4 39: Specific Earth Resistance (Ro) measurement menu
Step 2
Set the following limit value:
• Distance: set distance "a" between test rods using the ▲▼ and ◀▶ navigation keys.
Step 3
Follow the connection diagram shown in figures 4.40 to perform the Specific Earth
Resistance measurement.
- 83 -
EN

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido