5
System Set Up
5.2 Connecting inputs/outputs
CNP1(WHT)
1
2
3
1
3
4
5
TBO.1
6
7
1
8
CNV1
9
(WHT)
10
5
11
12
13
14
1
2
3
4
5
6
TBO.2
7
8
9
10
11
12
13
14
1
1
CNBH
CNIH
(WHT)
3
(ORN)
7
3
1
1
CNBC
CNBHT
2
(GRY)
(BLK)
3
1
3
1
CN21
CNW12
CN2F
CNW5
CN20
(YLW)
(YLW)
(RED)
(WHT)
(RED)
1
1
1
1
1
2
3
2
3
4
2
4
6
8
10
12 14
2
1
3
5
7
9
11 13
1
3
TBI.1
<Figure 5.2.1>
Signal inputs
Name Terminal block Connector Item
IN1
TBI.1 1-2
—
IN2
TBI.1 3-4
CN2F
IN3
TBI.1 5-6
—
IN4
TBI.1 7-8
—
IN5
TBI.1 9-10
—
IN6
TBI.1 11-12
—
IN7
TBI.1 13-14
—
*1. If using outdoor thermostat for controlling operation of heaters, the lifetime of the heaters and related parts may be reduced.
*2. To turn on the boiler operation, use the main controller to select "Boiler" in "External input setting" screen in the service menu.
Wiring specification and field supply parts
Item
Name
Model and specifications
Signal input
Signal input
Use sheathed vinyl coated cord or cable.
function
wire
Max. 10 m
Wire type: CV, CVS or equivalent
Wire size: Stranded wire 0.5 mm² to 1.25 mm²
Switch
Non-voltage "a" contact signals
Remote switch: minimum applicable load 12V DC, 1mA
Thermistor inputs
Name
Terminal block Connector
TH1
—
CN20
TH2
—
CN21
THW1
—
CNW12 1-2 Thermistor (Flow water temp.)
THW2
—
CNW12 3-4 Thermistor (Return water temp.)
THW5
—
CNW5
THW6
TBI.2 7-8
—
THW7
TBI.2 9-10
—
THW8
TBI.2 1-2
—
THW9
TBI.2 11-12
—
THWB1 TBI.2 3-4
—
THWB2 TBI.2 5-6
—
Do not splice the wiring to extend or shorten it, or this could affect correct monitoring of each temperature.
If the wiring is too long, bundle it with a strap to adjust the length.
*1. The maximum length of the thermistor wiring is 5 m.
When the wires are wired to adjacent terminals, use ring terminals and insulate the wires.
CN01
5
(BLK)
1
CN3C
1
(BLU)
3
FT C 4
LED3
1
CN105
(RED)
5
1
CNRF
(WHT)
5
CNPWM
LED4 LED5
(WHT)
LED2
CN22
(BLU)
CN108
CNW3
SW4
(WHT)
1
LED1
1
6
2
SW2
SW1
8
8
1
1
4
6
8
10
12 14
SW3
5
7
9
11 13
8
1
TBI.2
Room thermostat 1 input
Flow switch 1 input
Flow switch 2 input (Zone1)
Demand control input
Outdoor thermostat input (*1)
Room thermostat 2 input
Flow switch 3 input (Zone2)
Solid wire: ø0.65 mm to ø1.2 mm
Item
Thermistor (Room temp.) (Option) *1
Thermistor (Ref. liquid temp.)
Thermistor (DHW tank water temp.)
Thermistor (Zone1 flow water temp.) (Option)*1
Thermistor (Zone1 return water temp.) (Option)*1
Thermistor (Zone2 flow water temp.) (Option)*1
Thermistor (Zone2 return water temp.) (Option)*1
Thermistor (Boiler flow water temp.) (Option)*1
Thermistor (Boiler return water temp.) (Option)*1
When the wires are wired to adjacent terminals use ring terminals and insu-
late the wires.
OFF (Open)
ON (Short)
Refer to SW2-1 in <5.1 Dip Switch Functions>.
Refer to SW2-2 in <5.1 Dip Switch Functions>.
Refer to SW3-2 in <5.1 Dip Switch Functions>.
Normal
Heat source OFF/ Boiler operation *2
Standard operation
Heater operation/ Boiler operation *2
Refer to SW3-1 in <5.1 Dip Switch Functions>.
Refer to SW3-3 in <5.1 Dip Switch Functions>.
Optional part model
PAC-SE41TS-E
—
—
—
—
PAC-TH011-E
PAC-TH011-E
PAC-TH011HT-E
28