3. Technical description

The technical specifications for the PSU01 (Evaluation Unit + sensor) are described below.

3.1 Position Supervisor Unit (Evaluation Unit)

Feature
Standard references
Housing material
Housing dimensions
Interfaces
Protocol
Connection type
Ambient operating temperature
Storage temperature
Humidity
Air pressure
Service life
Degree of protection
Supply voltage
Power
Maximum distance to the encoder
Deactivation time / system response
time
Maximum number of floors
EN - page 12 (R60953.0009 3)
Value
EN81-20, EN81-50, EN81-21
Plastic
70 mm (H) x 95 mm (L) x 30 mm (W)
2 x CAN (internal and public) , 1 x SSI (optional)
Internal: proprietary, public: CANopen, SSI: 2 x 25 bit with
PFB, grey code, MSB-first
picoMAX
From -5°C to +55°C
From -10°C to +70°C
< 90% (non-condensing)
800 - 1013 hPa (up to 2000 m over sea level)
20 years
IP00 (min. IP20 when installed in the switching cabinet)
24 VDC low-voltage PELV
< 10 watts
100 m (internal CAN bus)
< 25 ms (incl. relay switching time)
200
All lines and trailing cables must be manufactured with dual insulation
or mechanically protected according to EN81-20 5.10.6.
In particular, make sure that they are routed without any short circuits.
eCOM 3.5, 7.5 (connection and chapter 5)
®