• In case of excessive capacitively coupled interference in the inspection circuit (see maintenance
instructions), they must be correctly eliminated by the customer using power resistors or capacitors.
• No users with a high interference level, such as frequency converters, solenoid valves, contactors,
etc. should be connected to the voltage supply of the electronics (PSU Evaluation Unit, Ants LES01,
control). Otherwise, a suitable voltage filter must be provided.
5.3 Electrical integration into the elevator system
This chapter describes PSU01 in the overall system and explains the electrical integration into the lift
system.
The figure below displays the correct integration of the PSU Evaluation Unit with Ants LES01 in the
elevator system.
emergency stop area
landing door contacts
lock contacts
car door contact