10.3. Technical data for Liftson lix L1

Liftson lix
Approved field of application
Max. intake/h:
Max. admissible pressure in
the discharge pipeline:
Max. delivery head [H]:
Max. permitted geodesic
delivery head:
Minimum flow rate [Q]:
Maximum flow rate [Q]:
Fluid temperature [t]:
Max. fluid temperature:
Ambient temperature:
Max. solid grain size:
Motor data
Mains connection [U/f]:
Type of connection:
Power consumption [P
]:
1
Rated power [P
]:
2
Rated current [I
]:
N
Speed [n]:
Activation type [AT]:
Protection class unit:
Switchgear protection class: IP 54
Max. switching operations/h: 30
Operating mode:
Connections
Pressure connection:
Inlet connection:
Ventilation connection:
Dimensions and weights
Gross volume:
Max. usable volume:
Switch-on level (for installa-
tion level):
Dimensions (WxHxD):
Diagonal dimension:
Sound-pressure level:
Weight:
The sound-pressure level depends on the duty point and may vary. Incorrect installation or impermissible operation can increase
3)
the sound-pressure level.
L1-10
L1-13
1050 l
1050 l
3 bar
3 bar
10 m
13 m
9 m
11.5 m
13 m³/h
13 m³/h
35 m³/h
36 m³/h
+3...+40 °C
+3...+40 °C
+60 °C for max.
+60 °C for max.
3 min
3 min
+3...+40 °C
+3...+40 °C
40 mm
40 mm
3~400 V/50 Hz
3~400 V/50 Hz
Switchgear with
Switchgear with
main switch
main switch
2.3 kW
2.6 kW
1.75 kW
2.1 kW
3.7 A
4.5 A
2870 rpm
2880 rpm
direct
direct
IP 67 (2 mWs/7 d)
IP 67 (2 mWs/7 d)
IP 54
30
S3 10 %/120 s
S3 10 %/120 s
DN 80
DN 80
DN 50, DN 100, DN
DN 50, DN 100, DN
150
150
DN 70
DN 70
115 l
115 l
35 l
35 l
175 mm
175 mm
630x590x770 mm
630x675x770 mm
945 mm
945 mm
< 70 dB(A)
< 70 dB(A)
3)
45 kg
47 kg
L1-16
1050 l
3 bar
16 m
14.5 m
13 m³/h
38 m³/h
+3...+40 °C
+60 °C for max.
3 min
+3...+40 °C
40 mm
3~400 V/50 Hz
Switchgear with
main switch
3.3 kW
2.6 kW
5.4 A
2850 rpm
direct
IP 67 (2 mWs/7 d)
IP 54
30
S3 10 %/120 s
DN 80
DN 50, DN 100, DN
150
DN 70
115 l
35 l
175 mm
630x675x770 mm
945 mm
< 70 dB(A)
3)
3)
47 kg
45
L1-19
L1-22
1050 l
1050 l
3 bar
3 bar
19 m
22 m
17 m
19.5 m
13 m³/h
13 m³/h
40 m³/h
40 m³/h
+3...+40 °C
+3...+40 °C
+60 °C for max.
+60 °C for max.
3 min
3 min
+3...+40 °C
+3...+40 °C
40 mm
40 mm
3~400 V/50 Hz
3~400 V/50 Hz
Switchgear with
Switchgear with
main switch
main switch
3.6 kW
4.2 kW
3.0 kW
3.5 kW
6.3 A
7 A
2920 rpm
2890 rpm
direct
direct
IP 67 (2 mWs/7 d)
IP 67 (2 mWs/7 d)
IP 54
IP 54
30
30
S3 10 %/120 s
S3 10 %/120 s
DN 80
DN 80
DN 50, DN 100, DN
DN 50, DN 100, DN
150
150
DN 70
DN 70
115 l
115 l
35 l
35 l
175 mm
175 mm
630x675x770 mm
630x675x770 mm
945 mm
945 mm
< 70 dB(A)
< 70 dB(A)
3)
53 kg
53 kg