Location Of Ice Machine; Clearance Requirements; Ice Machine Heat Of Rejection - Motak PKU0155SA Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation Instructions

Location of Ice Machine

The location selected for the ice machine must meet the following criteria. If any of these
criteria are not met, select another location.
• The location must be free of airborne and other contaminants.
• The air temperature must be at least 40°F (4°C), but must not exceed 110°F (43.4°C).
• The location must not be near heat-generating (ovens, dishwashers, etc.) equipment or
in direct sunlight and must be protected from weather.
• The location must not obstruct airflow through or around the ice machine. Refer to the
clearance requirements chart.

Clearance Requirements

PKU0155 Top and Sides 5" (13 cm) Back 5" (13 cm)
PKM0335 Top and Sides 8" (20 cm) Back 5" (13 cm)
PKM0425 and PKM0535 Top and Sides 8" (20 cm) Back 5" (13 cm)
Do not obstruct ice machine vents or openings.

Notice
The ice machine must be protected if it will be subjected to temperatures below
32°F (0°C). Failure caused by exposure to freezing temperatures is not covered by the
warranty.

Ice Machine Heat of Rejection

Series
Ice Machine
PKU0155
PKM0335
PKM0425
PKM0535
1 B.T.U./Hour
2 Because the heat of rejection varies during the ice making cycle, the figure shown is an average.
Ice machines, like other refrigeration equipment, reject heat through the condenser.
It is helpful to know the amount of heat rejected by the ice machine when sizing air
conditioning equipment where self-contained air-cooled ice machines are installed.
12
Heat of Rejection
Air Conditioning
2
2200
4600
5400
5300
Part Number: 000016426 Rev 00 08/2020
Section 1
1
Peak
2600
5450
6300
6100