Remedial Descaling Procedure - Motak PKU0155SA Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Cleaning and Sanitation

Remedial Descaling Procedure

This procedure descales all components in the water flow path and is used between the
bi-yearly detailed descaling and sanitizing procedure.
Ice machine descaler is used to remove lime scale and mineral deposits. Ice machine
sanitizer disinfects and removes algae and slime.
NOTE: Although not required and dependent on your installation, removing the ice
machine top cover may allow easier access.
Step 1
Ice must not be on the evaporator during the cycle. Follow one of the methods
below:
• Move the toggle switch to the OFF position at the end of a harvest cycle after ice falls
from the evaporator.
• Move the toggle switch to the OFF position and allow the ice to melt.

Notice
Never use anything to force ice from the evaporator. Damage may result.
Step 2
Open the front door and move the toggle switch to the CLEAN or WASH position.
Wait until the water trough refills (approximately 1 minute) and then add the proper
amount of ice machine descaler to the water trough.
PKU0155
PKM0335/PKM0425/PKM0535
Step 3
After 1 minute place the toggle switch in the ICE or ON position and close and
secure the front door. The ice machine will automatically start ice making after the cycle is
complete (approximately 24 minutes).
40
Model
Amount of Descaler
2 ounces (60 ml)
5 ounces (150 ml)
Part Number: 000016426 Rev 00 08/2020