Water Supply And Drain Requirements; Water Inlet Lines - Motak PKU0155SA Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Section 1

Water Supply and Drain Requirements

Water Supply
Local water conditions may require treatment of the water to inhibit scale formation, filter
sediment, and remove chlorine odor and taste.
Warning
n
Connect to a potable water supply only. Plumbing must conform to state, local and
national codes.

WATER INLET LINES

Follow these guidelines to install water inlet lines:
• If you are installing a water filter system, refer to the installation instructions supplied
with the filter system for ice making water inlet connections.
• Do not connect the ice machine to a hot water supply. Be sure all hot water restrictors
installed for other equipment are working. (For example: check valves on sink faucets,
dishwashers, etc.)
• If water pressure exceeds the maximum recommended pressure of 80 psi (552 kPa),
obtain a water pressure regulator from your local plumbing supplier.
• Install a water shut-off valve for both the ice making and condenser water lines.
• Insulate water inlet lines to prevent condensation.

Notice
Do not apply heat to water valve inlet fitting. This will damage plastic water inlet
connection.
Part Number: 000016426 Rev 00 08/2020