n
All electrical work, including wire routing and grounding must conform to all applicable
national and local electrical codes.
Minimum Circuit Ampacity
The minimum circuit ampacity is used to help select the wire size of the electrical supply.
(Minimum circuit ampacity is not the ice machine's running amp load.)
Electrical Requirements
Refer to Ice Machine Model/Serial Plate for voltage/amperage specifications.
• A separate fuse/circuit breaker must be provided for each ice machine. Circuit breakers
must be H.A.C.R. rated in U.S.A.
• The wire size (or gauge) is dependent upon location, materials used, length of run, etc.,
so it must be determined by a qualified electrician.
• The ice machine must be grounded. Check all green ground screws in the control box
and verify they are tight before starting the ice machine.
• The maximum allowable voltage variation is ±10% of the rated voltage at ice machine
start-up (when the electrical load is highest).

Notice
Observe correct polarity of incoming line voltage. Incorrect polarity can lead to erratic
ice machine operation. Operate equipment only on the type of electricity indicated on
the specification plate.