General information

Overview
Contents
Guarantee / Safety ............................26
Main statutory instruments ................26
Overview............................................27
Characteristics of use........................28
Technical data
See technical data N° 13013498
Assembly ...........................................29
Gas/Electrical connections ................30
Fuel oil connection ............................31
Preliminary checks ............................32
Settings ....................................32 to 38
program .............................................41
Control panel TC ...............................42
Fuel oil firing......................................43
Safety checks ....................................44
Gas firing ...........................................45
Maintenance .....................................46
Maintenance gas .............................47
Maintenance fuel oil........................48
26
Guarantee
Installation and start up must be
performed in accordance with current
accepted practices by a qualified
technician. Current regulations , as well
as the following instructions must be
complied with. Any failure, however
minor, to observe these provisions shall
absolve the manufacturer from any
liability.
Also see:
guarantee enclosed with burner,
-
conditions of sale.
-
Safety
The burner is designed to be installed
on a generator connected to exhaust
pipes used for combustion products in
working conditions.
It should be used in an area where an
adequate supply of fresh air is available
for correct combustion and where any
vitiated products can be properly
evacuated.
Flue size and design mut be
appropriate to the fuel, in accordance
with current regulations and standards.
Power supply (230VAC%, 50Hz
the control and safety unit, as well as to
cut-off devices used, must include an
earthed neutral wire.
Otherwise, power supply to the burner
must include an isolating transformer
and appropriate protection (30mA
circuit breaker and fuse).
Burner must be able to be isolated from
the system via a multipole switch
complying with current standards.
Operating staff should always act with
extreme caution and especially avoid
direct contact with areas that are not
heat-insulated and electrical circuits.
Do not splash water on the burner's
electrical components.
In the event of flooding, fire, fuel
leakage or any other dangerous
situation (smell, suspicious sounds,
etc.), stop burner, cut main power
supply and fuel supply and call a
qualified technician.
Furnaces and their accessories, flues
and connection pipes must be
maintained, cleaned, and swept at least
once a year and prior to starting up
burner. Consult current regulations.
06/2006 - Art. Nr. 13 013 497B
Main statutory instruments "FR"
· Dwellings:
-
French Order dated 2
1977 and later modifying /
supplementary orders: Technical
and safety regulations governing
combustible gas and liquified
hydrocarbon installations located
inside dwellings and their
outbuildings.
-
DTU Standard P 45-204: Gas
installations (formely DTU n° 61-1 -
Gas installations - April 1982 +
later addendums).
-
DTU Standard 65.4 - Boiler house
technical provisions.
-
French NF Standard C15-100 +
Low voltage electrical installation
regulations.
-
French Departmental health
regulations.
· Public Buildings.
-
Public building fire and panic
prevention safety regulations.
General provisions:
GZ sections (combustible gas and
-
±1%
) to
liquified hydrocarbons);
CH sections (heating, ventilation,
-
cooling, air conditioning and steam
and domestic hot water production);
Provisions specific to each type of
public building.
Outside "FR"
Refer to local regulations.
nd
August