Leroy-Somer Digidrive SK Serie Guía De Usuario página 68

Ocultar thumbs Ver también para Digidrive SK Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Français
Figure 6-3 Pr 05 = AI.Pr
EUR
Remote speed
reference input
_
+
V
+24V
0V
T4
B7
Reference selected
0
0
0
1
1
0
1
1
Figure 6-5 Pr 05 = PAd
EUR
_
+
V
+24V
0V
When Pr 05 is set to PAd to implement a forward/reverse switch, see the Digidrive SK
Advanced User Guide.
When Pr 05 is set to E.Pot, the following parameters are made available for adjustment:
Pr 61: Motorised pot up/down rate (s/100%)
Pr 62: Motorised pot bipolar select (0 = unipolar, 1 = bipolar)
68
English
T1
0V
Remote current speed
T2
reference input (A1)
T3
+10V reference output
T4
Reference select
Analog output
B1
(motor speed)
B2
+24V output
Digital output
B3
(zero speed)
Drive Enable/Reset
B4
(USA: Not stop)
Run Forward
B5
(USA: Run)
Run Reverse
B6
(USA: Jog)
B7
Reference select
A1
Preset 2
Preset 3
Preset 4
T1
0V
T2
Not used
T3
+10V reference output
T4
Not used
Analog output
B1
(motor speed)
B2
+24V output
Digital output
B3
(zero speed)
B4
Drive Enable/Reset
B5
Forward/Reverse
B6
Not used
B7
Not used
Deutsch
Italiano
Figure 6-4 Pr 05 = Pr
EUR
_
V
+24V
0V
T4
B7
0
0
0
1
1
0
1
1
Figure 6-6 Pr 05 = E.Pot
EUR
_
V
+24V
0V
Digidrive SK Getting Started Guide
Español
T1
0V
T2
Not used
T3
+10V reference output
T4
Reference select
+
Analog output
B1
(motor speed)
B2
+24V output
Digital output
B3
(zero speed)
Drive Enable/Reset
B4
(USA: Not stop)
Run Forward
B5
(USA: Run)
Run Reverse
B6
(USA: Jog)
B7
Reference select
Reference selected
Preset 1
Preset 2
Preset 3
Preset 4
T1
0V
T2
Not used
T3
+10V reference output
T4
Down
+
Analog output
B1
(motor speed)
B2
+24V output
Digital output
B3
(zero speed)
Drive Enable/Reset
B4
(USA: Not Stop)
Run Forward
B5
(USA: Run)
Run Reverse
B6
(USA: Jog)
B7
Up
Issue Number: a

Publicidad

Tabla de contenido
loading

Tabla de contenido