Quick Start Commissioning; Terminal Control - Leroy-Somer Digidrive SK Serie Guía De Usuario

Ocultar thumbs Ver también para Digidrive SK Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Français
7

Quick Start Commissioning

This procedure is written from default parameter settings as the drive would be
delivered from the factory.
7.1

Terminal control

Figure 7-1 Minimum required control terminal connections
EUR
10k
(2kmin)
Speed
potentiometer
Terminal B7 open: Local voltage speed reference (A2) selected
Digidrive SK Getting Started Guide
Issue Number: a
English
Deutsch
T1
0V
Remote current speed
T2
reference input (A1)
T3
+10V reference output
Local voltage speed
T4
reference input (A2)
Analog output
B1
(motor speed)
B2
+24V output
Digital output
B3
(zero speed)
B4
Drive Enable/Reset
B5
Run Forward
B6
Run Reverse
Local (A2)/Remote (A1)
B7
speed reference select
Italiano
USA
10k
(2kmin)
Speed
potentiometer
Español
T1
0V
Remote current speed
T2
reference input (A1)
T3
+10V reference output
Local voltage speed
T4
reference input (A2)
Analog output
B1
(motor speed)
B2
+24V output
Digital output
B3
(zero speed)
B4
Not Stop
B5
Run
B6
Jog
Local (A2)/Remote (A1)
B7
speed reference select
81

Publicidad

Tabla de contenido
loading

Tabla de contenido