No
Function
44
Serial comms address
Defines the unique address for the drive for the serial interface.
No
Function
45
Software version
Indicates the version of software fitted to the drive.
Pr 46 to Pr 51 appear when Pr 12 is set to control a motor brake.
No
Function
46
Brake release current threshold
47
Brake apply current threshold
Defines the brake release and brake apply current thresholds as a % of motor current.
If the frequency is >Pr 48 and the current is >Pr 46, the brake release sequence is started.
If the current is <Pr 47, the brake is applied immediately.
No
Function
48
Brake release frequency
49
Brake apply frequency
Defines the brake release and brake apply frequencies.
If the current is >Pr 46 and the frequency is > Pr 48, the brake release sequence is
started.
If the frequency is <Pr 49 and the drive has been commanded to stop, the brake is
applied immediately.
No
Function
50
Pre-brake release delay
Defines the time between the frequency and load condition being met and the break
being released. The ramp is held during this time.
No
Function
51
Post brake release delay
Defines the time between the brake being released and the ramp hold being released.
Digidrive SK Getting Started Guide
Issue Number: a
English
Deutsch
Italiano
Range
0 to 247
Range
1.00 to 99.99
Range
0 to 200 %
Range
0.0 to 20.0 Hz
Range
0.0 to 25.0 s
Range
0.0 to 25.0 s
Español
Defaults
Type
1
RW
Defaults
Type
RO
Defaults
Type
50
RW
10
Defaults
Type
1.0
RW
2.0
Defaults
Type
1.0
RW
Defaults
Type
1.0
RW