CARE AND MAINTENANCE
At least twice each year, lower the canopy to check the downrod assembly, and then tighten all
screws on the fan . Clean the motor housing with only a soft brush or lint-free cloth to avoid scratching
the finish. Clean the blades with a lint-free cloth. You may occasionally apply a light coat of furniture
polish to wood blades for added protection .
Bulb Replacement: Use 13-watt max . GU24 bi-pin base CFL bulbs .
Impootaat:
Shut off the main power supply before you begin any maintenance tasks . Do not use
water or a damp cloth to clean the ceiling fan .
TROUBLESHOOTING
PROBLEM
The fan does not
move .
The fan is noisy .
POSSIBLE CAUSE
1 . The power is off or the fuse is
blown .
2 . There is a faulty wire connection .
3 . The plugs are not connected
properly .
4 . The DC motor is obstructed
during operation .
5 . The power of the motor is over
80W .
1 . The blades are loose .
2 . There is a cracked blade .
3 . The wall control is not compatible
with the fan .
4 . The break-in period has not
surpassed .
5 . The outlet box is not secure .
6 . The mounting bracket is not
secure .
CORRECTIVE ACTION
1 . Turn the power on or check the
fuse .
2 . Turn the power off . Loosen
the canopy and check all
connections .
3 . Check that the connectors from
the light kit fitter and fan are
connected properly .
4 . Disable the power supply to the
fan motor and re-start the motor .
5 . The blade is overweight . Do not
install the unapproved blades .
1 . Check and tighten all screws
that hold the fan blades to the
blade arms and the motor .
2 . Replace the cracked blade .
3 . Do not use a full range dimmer
switch to control the fan speed .
4 . Run the fan continuously for 24
- 48 hours on medium or high
speed for a break-in period .
5 . Ensure the outlet box is secured
to the building structure .
6 . Ensure the mounting bracket is
secured to the outlet box and
that the screws are tight .
18