cap.11 EU65is 6500is 07.12.17 5:03 PM ページ11-4
IGNITION PULSE GENERATOR INSTALLATION
1) Install the ignition pulse generator and loosely install the
ignition pulse generator bracket mounting bolts (6 x 25 mm
flange bolt).
• Take care not to pinch the generator wire harness with the
ignition pulse generator bracket.
2) Insert a appropriate feeler gauge between the ignition
pulse generator and projection part of the rotor.
Air gap (at rotor)
3) Push the ignition pulse generator firmly against the rotor
and tighten the ignition pulse generator bracket mounting
bolt. Remove the feeler gauge.
b. INSPECTION
Measure the resistance between the terminal and the ignition
pulse generator base.
Resistance
11-4
0.5 ± 0.2 mm (0.02 ± 0.01 in)
297 – 363 Ω
[1]
6 x 25 (2)
IGNITION PULSE
GENERATOR BRACKET
[2]
GENERATOR
WIRE HARNESS
0.5 ± 0.2 mm (0.020 ± 0.008 in)
[2]
PROJECTION POINT
[1]
FEELER
GAUGE