cap.02 EU65is 6500is-2 (E) 07.12.17 5:56 PM ページ2-47
Check whether the auto choke shaft has closed with engine
switch turned ON.
• Choke valve will be closed fully once, then will be adjusted
automatically according to the temperature of the cylinder
head when the ignition switch is turned ON.
CHOKE SHAFT
Check the choke control motor (P. 4-10).
Check the harness connecting the choke control motor and
GCU for open or short circuit and for proper connection.
Wire harness check points
ENGINE WIRE
HARNESS
CONTROL WIRE
HARNESS
Viewed from terminal side
2-47
From P. 2-46
Abnormal
Normal
CHOKE
W
Y
R Bu
CONTROL
MOTOR
GCU
Y
Bu
R
W
Bu: BLUE
W: WHITE
Y: YELLOW
R: RED
Normal
Go to P. 2-48
Normal
Turn the ignition switch OFF and
then restart the engine and
recheck. Replace the inverter unit
if necessary (P. 6-2).
Abnormal
Replace the choke control motor
(P. 4-6).
Abnormal
Replace or repair the engine wire
harness and/or control wire
harness.