Nice RUN400HS Instrucciones Y Advertencias Para La Instalación Y El Uso página 21

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 55
WARNINGS: • All technical specifications stated in this section refer to an ambient temperature of 20°C (± 5°C). • Nice S.p.a. reserves the right to apply
modifications to products at any time when deemed necessary, maintaining the same intended use and functionality.
Model:
Type
Pinion
Maximum torque on start-up [cor-
responds to ability of generating the
force required to move the leaf]
Nominal torque [corresponds to the
ability of generating the force to main-
tain the leaf in movement]
Speed (no load)
Speed (at nominal torque)
Maximum frequency of operating
cycles (at nominal torque)
Maximum time of continuous
operation (at nominal torque)
Operating limits
Durability
Power: RUN 400HS - 1200HS
Versione V1
Maximum power absorption on
start-up [corresponding to Amps]
Insulation class
Flashing light output
Gate open indicator output
BLUEBUS output
STOP input
Step-by-step input
OPEN input
CLOSE input
Radio connector
Radio ANTENNA input
Programmable functions
Functions in self-learning mode
Operating temperature
Protection rating
Dimensions and weight
* 12 tooth modulus 6 pinion available as option .
** At 50°C and with a gate of 15 metres, the maximum operating frequency is 7 cycles/hour (equal to a cycle of 40%) .
*** At 50°C the maximum continuous operation time is 10 minutes .
TECHNICAL SPECIFICATIONS OF PRODUCT
RUN400HS - RUN400HS/V1
Electromechanical gearmotor for automatic movement of sliding gates for industrial use complete with elec-
tronic control unit .
Number of teeth 18; Module 4 *
12,3 Nm
(340 N)
5,6 Nm
(157 N)
42 m/min
32 m/min
11 cycles/hour (264 cycles/day), for a gate of 15m
(equal to a cycle of 63%), (the control unit limits cycles
to the maximum number specified in tables 2 and 3)**
40 minutes (the control unit limits continuous operation
to the maximum limits as specified in tables 2 and 3)***
In general RUN is designed for the automation of gates with the weights and lengths as specified
Estimated between 150.000 cycles and 450.000 cycles according to conditions specified in Table 4
230V AC (+10% -15%) 50 Hz.
120Vac 50/60 Hz
510 W
(4,7 A)
1 (safety earthing required)
For 2 Flashing lights LUCYB (lamp 12V, 21W)
For 1 24V lamo of maximum 4W (output voltage may vary between -30 and +50% and can also control small
relays)
One output with a maximum load of 15 BlueBus units
For normally closed or normally open contacts, for 8.2 kΩ constant resistance; with self-recognition (any varia-
tion from the memorized status causes the "STOP" command)
For normally open contacts (contact closure generates S .S . command)
For normally open contacts (contact closure generates OPEN command)
For normally open contacts (contact closure generates the CLOSE command)
SM connector for receivers SMXI; SMXIS or ONEXI
Input ANTENNA Radio 52Ω for cable type RG58 or similar
8 ON-OFF type functions and 8 settable function (see tables 7 and 9)
Self-learning of devices connected to BlueBus output
Self-learning of "STOP" device type (contact NO, NC or 8,2KΩ resistance)
Self-learning of gate length and calculation of deceleration and partial opening points
-20°C . . . 50°C
IP 44
400 x 255 h 390 mm; 24 .5kg
RUN1200HS - RUN1200HS/V1
28,4 Nm
(790 N)
8,2 Nm
(320 N)
22 m/min
19 m/min
7-8 cycles/hour (365 cycles/day), for a gate of 15m
(equal to a cycle of 63%), (the control unit limits cycles
to the maximum number specified in tables 2 and 3)**
60 minutes (the control unit limits continuous operation
to the maximum limits as specified in tables 2 and 3)***
550 W
(5,2 A)
15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Run400hs/v1Run1200hsRun1200hs/v1

Tabla de contenido