Control Cabinet - Bosch EPS 625 Manual Original

Ocultar thumbs Ver también para EPS 625:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 118
en
50 | EPS 625 | Product description
Vertical MGT adjustment
To move the MGT vertically, loosen the screw
(Fig. 5, Pos. 4). Then, rotate the hexagon bush
(Fig. 5, Pos. 1). The MGT can traverse 150 mm vertically
to adjust the height for different lengths of high pres-
sure pipes. The swing arm can be fixed in the required
position by tightening the allen bolt on the clamping
piece.
3.5.6

Control cabinet

DANGER: Risk of electric shock from live
parts
Touching live parts in the control cabinet
might result in shock and fatal injury or
death.
Work in the control cabinet is only to be
performed by qualified electricians or au-
thorized personnel under the supervision
of a qualified electrician.
Cover or cordon off live parts.
All the electrical components and control elements
required for operation are located in the control cabinet
(Fig. 6). The control cabinet is fixed to the test bench
frame.
|
1 689 988 258
2017-05-30
1
3
Fig. 6:
Control cabinet
1 Frequency drive
2 Braking resistor
3 Logic board
4 RFI filter
5 Transformer
DANGER: Risk of electric shock from live
parts
Touching the frequency drive or the braking
resistor may result in electric shock even
after the mains supply is switched off.
Disconnect the mains supply.
Do not touch the frequency drive or the
braking resistor for 10 minutes after
switching off the mains supply.
2
4
5
Robert Bosch GmbH