en
60 | EPS 625 | Initial start-up
1
2
Fig. 19:
Terminal block for additional 230 V AC power supply
1 Phase
2 Neutral conductor
3 Protective conductor
i
Heed the circuit diagram.
8. Connect the cable of the multiple socket outlet as
follows:
$
Phase to terminal 16.
$
Neutral conductor to terminal 17.
$
Protective conductor to terminal PE.
Danger - Risk of electric shock from live
parts
Electric shocks resulting from contact with
live parts (e.g. master switch, printed cir-
cuit boards) can cause injury, heart failure
and fatality.
¶
Work on electrical installations or equip-
ment is only to be performed by quali-
fied electricians or trained personnel
under the guidance and supervision of
an electrician.
¶
Cover or cordon off live parts.
¶
Never touch live parts or parts with dam-
aged insulation.
9. Switch on the EPS 625.
10. Use a multimeter to check the voltage between the
phase and neutral conductor at the multiple socket
outlet.
The voltage must be 230 V AC 10 %.
|
1 689 988 258
2017-05-30
3
i
The power supply must be checked if the voltage is
not 230 V AC 10 %. Check the protective conduc-
tor.
11. Position the multiple socket outlet in a safe loca-
tion.
12. Close the switch cabinet
"
This completes connection of the additional power
supply.
4.4.4
HMI connection
1. Open either the motor RH or LH panel
(Fig. 20, Pos. 1).
Fig. 20:
Opening the motor RH panel
1 Motor RH panel
2 HMI mounting tray
2. Detach the HMI cable from the cable holder.
3. Fix the HMI cable to the connector of the HMI unit
and tighten.
4. Place the HMI on the HMI mounting tray
(Fig. 20, Pos. 2).
5. Open the plug (Fig. 22, Pos. 1).
6. Unfasten the HMI locking screw (Fig. 21, Pos. 4) and
remove the HMI locking mechanism.
Fig. 21:
HMI unit
1 Nylon washer
2 Plain washer
3 Spring
4 Locking screw
2
1
1
2
3
4
Robert Bosch GmbH