Connecting A Radio Receiver; Connecting The Pole Lights (Optional Accessory); Connection Of Other Devices; Programming Unit Oview - Nice MBar Serie Instrucciones Y Advertencias Para La Instalación Y El Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 81
CAUTION – If the manoeuvre starts from a position different from that of one
of the mechanical stops (opening or closing), it is performed at low speed.

4.7 - Connecting a radio receiver

The control unit is fitted with a SM type connector for connection of a radio
receiver (optional accessory) model SMXI, SMXIS, OXI or OXIT and similar.
To insert the radio receiver, disconnect the control unit from the power mains
and insert the receiver as shown in fig. 42.
Table 5 shows the actions performed by the control unit according to the out-
puts activated or the commands sent from the radio receiver.
SMXI, SMXIS, OIX, OXIT receiver in mode I or II
output
description
Output no. 1
Step by step
Output no. 2
Partial Open (opens to approx. 45%;
value programmable with Oview, see paragraph 4.10.1)
Output no. 3
Open
Output no. 4
Close
OXI receiver, OXIT programmed in "Extended Mode II"
Command
description
Command no. 1
Step by step
Command no. 2
Partial Open (opens to approx. 45%;
value programmable with Oview, see paragraph 4.10.1)
Command no. 3
Open
Command no. 4
Close
Command no. 5
Stop
Command no. 6
Apartment block Step by Step
Command no. 7
Step-Step High priority
(controls also if automation is blocked)
Command no. 8
Unblock + Open
Command no. 9
Unblock + Close
Command no. 10
Open and block automation
Command no. 11
Close and block automation
Command no. 12
Block automation
Command no. 13
Release automation
Command no. 14
Master door Step by Step
Command no. 15
Slave door Step by Step

4.8 - Connecting the pole lights (optional accessory)

01. Move the pole to the vertical position;
02. Unscrew the 6 screws that hold the pole cover (Fig. 43);
03. Remove the pole temporarily;
04. Insert the grommet in the pre-drilled hole for cable routing (Fig. 44);
05. Route the lights cable through the impact protection rubber profile, using a
guide to facilitate attachment if necessary (Fig. 45);
06. If necessary, shorten the length of the lights cable: cuts may only be made
at the points bearing the relative mark. After cutting, the plug at the cut end
must be moved to seal off the new end;
07. Insert the cable first through the hole on the pole support and then through
the hole on the cabinet (Fig. 46); Caution – Leave a little extra cable in the
pole support, to enable pole rotation through 90° without tensioning the
cable;
08. Connect the lights cable to the LIGHT terminal on the control unit: see dia-
gram in Fig. 47. Note – The LIGHT output features polarity: if the lights do
not illuminate, as planned, it is necessary to invert the cables connected to
the terminal.
09. Position and secure the connector in the slot on the pole (Fig. 48);
10. Insert the pole and secure with its cover, tightening the 6 screws (fig. 49)
fully down and taking care not to pinch the wiring cable.
4.9 - Connecting the LED flashing light mod. XBA7 or LED traf-
fic light mod. XBA8 (optional accessories)
On the cover of the barrier a LED flashing light mod. XBA7 or red and green
LED traffic light mod. XBA8 may be fitted. The operating modes of these flash-
ing lights may be modified through the Oview programmer or with suitable pro-
grammes of the control unit. For further information, refer to the instruction
manual for the two products.

4.10 - Connection of other devices

The built-in unit enables the power supply to the external devices (a radio
receiver or the key-operated selector switch lighting) by receiving power from
the control unit: for the type of connection, see fig. 41.
The power supply voltage is 24 Vdc, -30%/+50%, with maximum available cur-
rent 100 mA.
8 – English
TABLE 5

4.10.1 - Programming unit Oview

The use of the programming unit Oview enables complete and rapid manage-
ment of installation, maintenance and troubleshooting of any malfunctions of
the whole automation system. Oview can be connected to the road barrier by
means of the BusT4 connector on the control unit.
To access the BusT4 connector, open the cover of the road barrier and insert
the connector in its seat (fig. 50).
In general, Oview can be positioned at a maximum distance of 100 m of cable
from the control unit; it can be connected to multiple control units simultane-
ously (max. 16) and can also remain connected during normal operation of the
automation; to exceed these limits, observe the warnings in the Oview instruc-
tion manual and the Oview System Book system manual. If a OXI type radio
receiver is present in the control unit, Oview enables access to the parameters
of the transmitters memorised in this receiver. For detailed information, refer to
the instruction manual of the Oview programmer or the barrier function
datasheet also available on the website www.niceforyou.com.

4.10.2 - Buffer battery mod. PS224 (accessory)

In the event of a mains power failure, the road barrier can also be powered by a
buffer battery model PS224. To install and connect the battery, proceed as fol-
lows:
Important! – The electric connection of the battery to the control unit
must only be made after completing all installation and programming
phases, as the battery constitutes an emergency power supply.
01. Position the buffer battery as shown in fig. 51-a;
02. Disconnect the mains power and then connect the relative cable of the
buffer battery (fig. 51);
03. Connect the mains power.

4.10.3 - Solemyo System (photovoltaic supply)

The barrier is designed to be powered with the "Solemyo SYKCE" photovoltaic
system. For connection to the control unit, use the 2 pole plug shown in fig. 52.
IMPORTANT!
- When the barrier is powered by the "Solemyo" system IT MUST NOT
BE POWERED by the electricity grid at the same time.
- Due to the limited solar power available, depending on the installa-
tion location and time of year, the barrier can perform a maximum
number of manoeuvres per day. Before installing the Solemyo sys-
tem, check in the relative instruction manual whether the maximum
number of possible manoeuvres is compatible with the intended use.
- The Solemyo system can only be used efficiently if the control unit is
active and set with the Standby function set to "All" mode (only pos-
sible using the Oview programmer).

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

M3barM5barM7barLbar

Tabla de contenido