GiBiDi BA24 Instrucciones De Instalación página 39

Ocultar thumbs Ver también para BA24:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 74
BA24
FINAL OPENING AND
C8
CLOSING STROKE
C9
SAFETY DEVICE
ANTI-CRUSHING /
C10
LIMIT SWITCH AMPEROMETRIC
COURTESY LIGHT
C11
WITH TWO MOTORS
C13
T3 ADDITIONAL TIME
C14
INVERSION FROM PEDESTRIAN
C15
FLASHING LIGHT
Enables the final opening and closing stroke.
Operation:
At the end of the working time during opening and closing without
deceleration, a 2 s pulse is given with the power set in menus F1 and F5.
When deceleration is active, the pulse is given at the end of the
Y
deceleration time.
The final stroke is regulated by the amperometric level in menus F3 and
F7.The final stroke is not controlled by the safety devices (edge/anti-
crushing).
Not active with the sliding configuration.
N
Disables the final closing stroke in opening and closing
8K2
Enables the edge provided with 8K2 in series resistance
Enables the edge provided with the N.C. contact (normally closed)
NC
ABILITATO AMPEROMETRICA DI FINE CORSA (The amperometric
inverts the motion).
Y1
NOTE: ENABLE THE ANTI-CRUSHING ONLY IF ALSO THE LIMIT
SWITCHES ARE ENABLED.
ENABLED LIMIT SWITCH AMPEROMETRIC (The amperometric stops
Y2
the motion)
N
Anti-crushing not enabled
Courtesy light activated with 2 motors.
Operation:
Y
Active on the electrical lock output 2 for 3 minutes after the end of the
motors movement.
N
Courtesy light not activated with 2 motors.
N
T3 excluded.
T3 = time set for deceleration (H3 – H6) with the same menu F1 and
YF
F5 settings
T3 = time set for deceleration (H3 – H6) with the same menus F2 and
YS
F6 settings
During the PEDESTRIAN closing, the PHOTO 1 – PHOTO 2 –
PEDESTRIAN command opens only the pedestrian.
Y
The START command causes the complete opening.
During the PEDESTRIAN closing, the PHOTO 1 – PHOTO 2 –
N
PEDESTRIAN – START command causes the complete opening.
Blinking flashing light output.
Y
Fixed flashing light output.
N
39
UK

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

S05100

Tabla de contenido