BA24
H5
25
MOTOR 2 CLOSING TIME
H6
20
MOTOR 2 DECELERATION TIME
H7
5
LEAF 2 PHASE SHIFT TIME IN OPENING
H8
5
LEAF 1 PHASE SHIFT TIME IN CLOSING
H9
5
PAUSE TIME
H10
5
PEDESTRIAN OPENING TIME
H11
5
PEDESTRIAN PAUSE TIME
NUMBER OF CYCLES
H12
0000
0000
H13
INSTALLER CODE
H14
xxxx
SOFTWARE VERSION (format: R__xx)
H15
0000
NUMBER OF CYCLES DONE
• Parameters type E:
E1
Y
PHOTOCELL 1 ENABLED
E2
Y
PHOTOCELL 2 ENABLED
E3
Y
SAFETY DEVICE (EDGE) ENABLED
FINAL CHECKS AND TESTING
Before powering the control unit , run the following tests:
1-
Check the electrical connections: improper connection may be harmful to both the control unit and the
operator.
2-
Check proper position of the limit switches.
3-
Preset the mechanical stops in opening and closing.
4-
Power the equipment.
5-
Check that the red LEDs of the normally closed contacts are on and the green LEDs of the normally open
contacts are off.
6-
Check that the writing SAF does not appear on the LCD (intercepted or faulty edge).
7-
Check that the relative LEDs turn off when limit switches work.
8-
Check that the relative LED turns off when the photocells ray is intercepted.
9-
Check that the relative LED turns off when the safety devices work.
10-
Check that the motors are locked and ready to work with the "GATE COMPLETELY CLOSED".
11-
Remove possible obstacles in the operating area of the gate, then give the command START. At the first
command, the equipment starts opening, then check that the motion direction is correct.
If not invert the wires in the terminals M1 and/or M2.
12-
The gate will stop upon reaching the first opening limit switch. It is necessary a complete movement to
activate the regular working of the decelerations.