42
UK
LEAF 2 PHASE SHIFT TIME
H7
IN OPENING
LEAF 1 PHASE SHIFT TIME
H8
IN CLOSING
AUTOMATIC CLOSING
H9
PAUSE TIME
H10
PEDESTRIAN OPENING TIME
AUTOMATIC PEDESTRIAN
H11
CLOSING PAUSE TIME
H12
CYCLES NUMBER
H13
INSTALLER CODE
H14
SOFTWARE VERSION
H15
NUMBER OF PERFORMED CYCLES
MENU E: EXTERNAL DEVICES ENABLING-DISABLING
KEY +: enters the following menu E1-E2-E3...
KEY - : accede al menu precedente E3-E2-E1...
KEY ESC: leaves the menu
KEY OK: enables (Y) / disables (N) the function
WARNING: The STOP key cannot be excluded in menu E. If it is not used, jumper the clamps 20-29.
Delay the start in opening of leaf 2 with respect to leaf 1.
In the case of double sliding gate, the time H7 will not be considered.
Tmax 100 sec.
Delay the start in opening of leaf 1 with respect to leaf 2. In the case of double
sliding gate, the time H8 will not be considered. Tmax 100 sec.
Determines the pause time in opening before automatic closing.
Tmax 300 sec.
Determines the pedestrian opening time.
Determines the pause time in pedestrian opening bifore automatic closing.
Tmax 300 sec.
Allows the setting of a number of cycles (opening+ closing) before the
maintenance request.
The value set will always be multiplied for 10.
If 0000 is set, the numbering is excluded.
When the set number of cycles is reached, the maintenance request is signalled
by a slow blink of 60 sec. at the end of the movement.
WARNING: every time you enter the menu H12 the cycles numbering is reset
and starts again.
Allows the input of the installer code to customize the settings during the
programming phase.
The INSTALLER CODE is the only way to enter the programming menu.
WARNING: in case of loss of the installer code, it will be possible to delete the
old one by pressing simultaneously the keys + and – for 3 seconds when the
writing PASS appears.
In this way, all the existing setting are erased and the default ones are
automatically set. Only the settings of the performed cycles are still stored in
memory.
Shows the firmware version installed on the equipment. (R__XX)
Number of performed cycles.
The value displayed on the LCD is increased every 10 movements.