SIMPLIFIED PROGRAMMING
1-
Connect all the connections (wire motors using a 1.5 mm² wire)
2-
Enter the installation code, and then set the type of function desired from menu A2/A3.
3-
Set the number of motors used. Menu A4/A5.
4-
Set the operation mode. Menu A6/A7/A8/A9.
5-
Go to menu C21, and select «Y» to activate automatic time programming, then press «START» (+ key) (see
page 20 "Time learning procedure")
6-
Go to menu C5 to program slowdowns.
7-
Go to menu C6 to choose the number of limit switches. We recommend programming a single limit switch
when stopping points are present.
8-
Use the dedicated menus to adjust each time parameter.
9-
Press «ESC» to exit programming.
10-
Check whether the force used by operators on the gate is either sufficient or excessive. Go to menu F to
adjust, if necessary.