Descargar Imprimir esta página

Publicidad

2.6
MAKING CONNECTIONS: Snap hooks and carabiners used with this equipment must be self-locking. Ensure all
connections are compatible in size, shape and strength. Do not use equipment that is not compatible. Ensure all
connectors are fully closed and locked.
3M connectors (snap hooks and carabiners) are designed to be used only as specified in each product's user's instructions.
See Figure 5 for examples of inappropriate connections. Do not connect snap hooks and carabiners:
A.
To a D-ring to which another connector is attached.
B.
In a manner that would result in a load on the gate. Large throat snap hooks should not be connected to standard
size D-rings or similar objects which will result in a load on the gate if the hook or D-ring twists or rotates, unless the
snap hook complies is equipped with a 3,600 lb (16 kN) gate. Check the marking on your snap hook to verify that it
is appropriate for your application.
C.
In a false engagement, where features that protrude from the snap hook or carabiner catch on the anchor, and
without visual confirmation seems to be fully engaged to the anchor point.
D.
To each other.
E.
Directly to webbing or rope lanyard or tie-back (unless the manufacturer's instructions for both the lanyard and
connector specifically allows such a connection).
F.
To any object which is shaped or dimensioned such that the snap hook or carabiner will not close and lock, or that
roll-out could occur.
G.
In a manner that does not allow the connector to align properly while under load.
10

Publicidad

loading

Este manual también es adecuado para:

Lad-saf x2