The display will show the work set-point during deep freezing. If it has been decided to
start the cycle with timed-control, the display will show the duration of time-controlled deep
freezing.
Press and release the UP or DOWN key within 15 s to modify the set point.
Press and release the START/STOP key: the
permanently on and the test to verify the correct insertion of the needle probe will be started.
If it has been decided to start the cycle with timed-control,
permanently on and the cycle will be started with timed-control.
If the test is completed successfully, the cycle will be started.
The maximum deep-freezing duration count is started on condition that the temperature
detected by the needle probe is below 65°C.
If the test is not completed successfully, the cycle will be started with timed-control.
During soft deep freezing, the display shows the residual time of the deep-freezing
duration and the
To modify the residual time, operate as indicated:
*
Press and release the UP or DOWN key again to modify the time value: the display will
flash.
*
Do not operate for 4 s: the display will stop flashing and remain on permanently.
*
During deep freezing, the display shows the residual time of the deep-freezing duration
and the
LED is on.
Operate as indicated to stop the cycle:
Hold the START/STOP key down.
During soft deep freezing, the display shows the temperature detected by the needle probe and
the
LED is on.
To display the cabinet temperature, press and release the BLAST CHILLING, DEEP FREEZING
or the HARD/SOFT key; to restore the normal display, press and release the same key again or
do not operate for 15 s.
When the temperature detected by the needle probe reaches 3°C, the device automatically
passes to deep freezing.
During deep freezing, the display shows the temperature detected by the needle probe and the
LED is on.
To display the cabinet temperature, press and release the DEEP-FREEZING key; to restore the
normal display, press and release the DEEP-FREEZING key again or do not operate for 15 s.
If the temperature detected by the needle probe reaches -18°C within 240 minutes, it means
that deep freezing has been completed successfully, the unit will automatically pass to storage
and the buzzer will be activated 5 seconds.
Press and release a key to silence the buzzer.
During storage, the display shows the temperature detected in the chamber and the
on.
If the temperature detected by the needle probe does not reach -18°C within 240 minutes, deep
freezing will not be completed successfully but will continue, the
buzzer will be activated.
Press and release a key to restore normal display and to silence the buzzer.
To display the cabinet temperature, press and release the DEEP-FREEZING key; to restore the
normal display, press and release the DEEP-FREEZING key again or do not operate for 15 s.
When the temperature detected by the needle probe reaches the deep-freezing end
temperature, the device automatically passes to storage in the same way as illustrated
previously.
LED is on.
17
LED and the
LED will remain
LED also the will remain
LED will flash and the
Blast Chillers
LED is
50LIB055