16-MAINTENANCE
•
Always disconnect the power plug BEFORE any maintenance operation.
•
Do not remove safety devices or guards before or during the cleaning!
The manufacturer declines all liability for accidents and damages caused due to lack of
compliance with this obligation.
•
The inside of the chamber must be cleaned at the end of every work day, in order to guarantee
hygiene and to safeguard the quality of the food products.
Clean with water and non-abrasive neutral detergents. Rinse with a light water jet or cloth/sponge
soaked in water
•
To access the evaporator for cleaning, use a Philips screwdriver to loosen the screws on the front
of the fan-holding panel open it.
In order to clean the evaporator, a soft brush can be used with a vertical movement along the
direction of the aluminum fins.
•
In order to maintain unit performance, we suggest to clean the condenser at least on a monthly
basis.
To remove the condenser protection grid loosen the four front screws, then lift up the grid and and
pull.
For the units equipped with a front filter remove it and vacuum all the dust from the filter. Gently
vacuum the front of the condenser to remove dust and debris.
If necessary it is possible to use a soft brush with a vertical movement along the direction of the
aluminum fins. In case of presence of oils on the condenser fins use of an alcohol soaked soft
brush is allowed.
50LIB055
28